A DIN-rail controller for the distribution board. It runs the Inspinia application on Linux, reports its status on a 1″ OLED, and reaches the building buses through two add-on ports.

UI objects
1000
Add-on bus ports
2
Max. consumption
2.5 W
DIN rail
TS35

At a glance

The controller on the rail

ARM A7 1.2 GHz, 128 MB RAM, 256 MB flash, Linux 3.4 with the Inspinia application. Initial licence 300 BMS points.

Two bus ports

Each takes an add-on module: KNX, SCS, iNELS, RS485 Modbus, VRF or Zigbee.

Status on the front

A 1″ mono OLED shows the unit’s status at the panel.

24 V DC or passive PoE

24 V DC in, or passive PoE over the LAN cable. Maximum 2.5 W.

Specification

As published in the datasheet.

Hardware and software

Processor
ARM A7 single-core 1.2 GHz
Memory
128 MB DDR3 RAM
Storage
256 MB NAND flash
Software
Linux 3.4 with the Inspinia application
Capacity
Up to 1000 UI objects and 2000 objects
Initial licence
300 BMS points · no HVAC points

Display

Status display
1″ OLED, mono colour

Power

Input
24 V DC or passive PoE
Consumption
Max. 2.5 W

Interfaces

LAN
1× RJ45 10/100 Mbps
Add-on
2× add-on ports

Environment

Operating temperature
−10 °C to +60 °C
Operating humidity
5% to 90% at 25 °C

Terminals

Power, network and both bus ports land on the module’s terminals.

  1. 24 V DC+ · − · power input
  2. EthernetRJ45 10/100 Mbps · LAN / passive PoE
  3. Add-on bus port 1A · B · C
  4. Add-on bus port 2A · B · C
  5. Status display1″ OLED, mono

Integrations

Optional interface modules fit the add-on port and bring the building’s buses and climate systems onto the same controller.

  • KNXA-KNXKNX TP
  • bticinoA-SCSBticino (SCS) TP
  • iNELSA-iBUSiNELS Bus TP
  • ModbusA-GRS4Galvanic isolated RS485 Modbus
  • VRFVRV / VRFOne add-on per AC brand · order codes below
  • ZigbeeA-ZGBZigbee 3.0

VRV / VRF port connection

BrandOrder codePortsProtocolIDUODU
DaikinA-VDKF1 · F2D3 NET6416
Hitachi · HisenseA-VHT1 · 2TCC LINK6416
LG · ArçelikA-VLGA · BINTER A-B64—
Mitsubishi ElectricA-VMEM1 · M2M-NET (TB3/7)5010
Mitsubishi HeavyA-VMHA · BSLINK I/II64—
Panasonic · SanyoA-VPAU1 · U2S3 NET64—
SamsungA-VSM-FF1 · F2 / R1 · R2NASA6416
ToshibaA-VTOU1 · U2TCC LINK6416

Indoor (IDU) and outdoor (ODU) unit counts are subject to limits set by the manufacturer. VRV/VRF add-ons always operate as the primary master central controller.

Bus connection

BusPortsProtocol
iNELS+ · −iNELS Bus
KNX+ · −KNX TP
ModbusA · B · GRS485
bticino+ · −SCS Bus

Dimensions and mounting

Dimensions
71.10 × 90.00 × 32.20 mm
Mounting
DIN rail TS35/7.5 or TS35/15
71.190
Outline · mm

Ordering and documents