Inspinia Mini Server
Server
A DIN-rail controller for the distribution board. It runs the Inspinia application on Linux, reports its status on a 1″ OLED, and reaches the building buses through two add-on ports.
- UI objects
- 1000
- Add-on bus ports
- 2
- Max. consumption
- 2.5 W
- DIN rail
- TS35
At a glance
The controller on the rail
ARM A7 1.2 GHz, 128 MB RAM, 256 MB flash, Linux 3.4 with the Inspinia application. Initial licence 300 BMS points.
Two bus ports
Each takes an add-on module: KNX, SCS, iNELS, RS485 Modbus, VRF or Zigbee.
Status on the front
A 1″ mono OLED shows the unit’s status at the panel.
24 V DC or passive PoE
24 V DC in, or passive PoE over the LAN cable. Maximum 2.5 W.
Specification
As published in the datasheet.
Hardware and software
- Processor
- ARM A7 single-core 1.2 GHz
- Memory
- 128 MB DDR3 RAM
- Storage
- 256 MB NAND flash
- Software
- Linux 3.4 with the Inspinia application
- Capacity
- Up to 1000 UI objects and 2000 objects
- Initial licence
- 300 BMS points · no HVAC points
Display
- Status display
- 1″ OLED, mono colour
Power
- Input
- 24 V DC or passive PoE
- Consumption
- Max. 2.5 W
Interfaces
- LAN
- 1× RJ45 10/100 Mbps
- Add-on
- 2× add-on ports
Environment
- Operating temperature
- −10 °C to +60 °C
- Operating humidity
- 5% to 90% at 25 °C
Terminals
Power, network and both bus ports land on the module’s terminals.
- 24 V DC+ · − · power input
- EthernetRJ45 10/100 Mbps · LAN / passive PoE
- Add-on bus port 1A · B · C
- Add-on bus port 2A · B · C
- Status display1″ OLED, mono
Integrations
Optional interface modules fit the add-on port and bring the building’s buses and climate systems onto the same controller.
A-KNXKNX TP
A-SCSBticino (SCS) TP
A-iBUSiNELS Bus TP
A-GRS4Galvanic isolated RS485 Modbus
VRV / VRFOne add-on per AC brand · order codes below
A-ZGBZigbee 3.0
VRV / VRF port connection
| Brand | Order code | Ports | Protocol | IDU | ODU |
|---|---|---|---|---|---|
| Daikin | A-VDK | F1 · F2 | D3 NET | 64 | 16 |
| Hitachi · Hisense | A-VHT | 1 · 2 | TCC LINK | 64 | 16 |
| LG · Arçelik | A-VLG | A · B | INTER A-B | 64 | — |
| Mitsubishi Electric | A-VME | M1 · M2 | M-NET (TB3/7) | 50 | 10 |
| Mitsubishi Heavy | A-VMH | A · B | SLINK I/II | 64 | — |
| Panasonic · Sanyo | A-VPA | U1 · U2 | S3 NET | 64 | — |
| Samsung | A-VSM-F | F1 · F2 / R1 · R2 | NASA | 64 | 16 |
| Toshiba | A-VTO | U1 · U2 | TCC LINK | 64 | 16 |
Indoor (IDU) and outdoor (ODU) unit counts are subject to limits set by the manufacturer. VRV/VRF add-ons always operate as the primary master central controller.
Bus connection
| Bus | Ports | Protocol |
|---|---|---|
| iNELS | + · − | iNELS Bus |
| KNX | + · − | KNX TP |
| Modbus | A · B · G | RS485 |
| bticino | + · − | SCS Bus |
Dimensions and mounting
- Dimensions
- 71.10 × 90.00 × 32.20 mm
- Mounting
- DIN rail TS35/7.5 or TS35/15
Ordering and documents
- MNSRVInspinia Mini Server
- DatasheetDatasheet — Inspinia Mini Server, opens in a new tab
- ConformityCE · RoHS
Start with the specification.
Send the protocol, the room count, and the panel sizes. We reply with a specification.